.. _intensity_view: Intensity View ============== .. |draw_roi_button| image:: img/draw_roi_button.png .. |to_qspace_button| image:: img/to_qspace_button.png .. figure:: img/intensity_view.png :width: 100% :align: center Intensity view By default, this view displays the total intensity summed over all scans for each point of the sample. Select displayed data --------------------- When an entry is selected in the list on the left, the scatter plot represents the intensity of the acquired images for the selected entry. When the **Total** item is selected, the total intensity of selected entries is displayed. It is possible to change the sorting of the scans by changing the selected positioner in the **Sort by** drop-down list (`eta` by default). It is possible to normalize the displayed data with the **Normalization** drop-down list. By clicking on a point of the scatter plot, you can display an intensity profile at that point in the lower part of the window. Shift scan sample positions --------------------------- It is possible to set some translation of sample position between different scans with the `Shift Editor`_. To open the `Shift Editor`_, click on the **Edit** button next to the **Apply Shift** checkbox. The **Apply Shift** checkbox toggles the usage of the current scan shifts. Shift Editor ............ .. figure:: img/shift_editor.png :width: 100% :align: center Shift Editor window The **Selection** frame on the left enables the selection of the **Displayed data** and to select a region of interest to be displayed in the central frame with the **ROI** selection tools and the the **View selection** button. The central frame allows to edit the shift by selecting reference position on 2 different scans. The right frame provides a **Preview** of the positions that are matched in the **Entries** tab and a preview of the integrated intensity in the **Intensity** tab. Do not forget to save the shift before closing the `Shift Editor`_ window with the **Save** button at the bottom. Prepare Q space conversion -------------------------- Click on the |to_qspace_button| button in the **ROI** frame on the right side of the window to start a Q space conversion of all sample points. This opens the :ref:`QSpace conversion dialog `. Select scans ............ To run a Q space conversion for a subset of the scans, select only the one that you want to use in the list on the left side of the window. Sample ROI selection .................... You can select a rectangular ROI to select the sample positions for which you want to run a QSpace conversion. To draw a ROI, click on the |draw_roi_button| button in the right frame and then draw the selected area on the scatter plot. Once this is done, click on the |to_qspace_button| button to open the :ref:`QSpace conversion dialog `.